Multichannel Decapper Selection Guide

Multichannel Decapper Selection Guide

Choosing between the 6- and 8-channel versions starts with one question: what volume are your SBS cryotubes? This guide maps whole-plate formats to item numbers, shows what a cryovial decapper recapper changes in a benchtop workflow, and lists the compatibility checks worth completing before you ask for pricing. As a semi automated cryovial decapper, it opens or closes caps in 3 seconds, runs at ≤5 dB during cap operations and holds ≥30 days of standby between sessions.

3 s Cap open and close cycle
≤5 dB Noise during capping
≥30 days Standby between runs
Semi-Automated Screw Cap Decapper/Recapper, Multichannel

Category scope

Manual, Semi-Automated or Fully Automated: Where This Unit Sits

All three approaches remove and replace caps on SBS cryotubes. They differ in how much of the rack the operator handles, how much bench space the equipment takes, and how much integration work sits between the decapper and the next step in the workflow.

01

Manual cap handling

Caps are loosened and tightened by hand or with a single-tube tool, one vial at a time, with the rack sitting open on the bench.

FitsSmall batches, mixed tube types and labs with no permanent bench position for a dedicated unit.

Trade-offRepetitive wrist work on full plates and a slower plate-to-plate turnaround.

02

Semi-automated multichannel — this unit

An operator loads a whole-plate SBS rack; 6 or 8 channels open or close the caps in 3 seconds, with an LED digital display screen on the second-generation lid opener.

FitsBiobank and core-lab workflows that process whole plates but do not need robotic integration.

Trade-offRacks are still transferred by hand between the decapper and the next station.

03

Fully automated line

Capping is one station inside a robotic liquid handler or track system, with no manual rack handling between steps.

FitsContinuous, high-volume lines where the decapper must hand off directly to downstream automation.

Trade-offIntegration engineering, a larger footprint and a longer validation cycle before first use.

Selection matrix

6-Channel or 8-Channel: Match the Plate to the Item Number

The two configurations are not interchangeable across vial volumes. The tube volume in the rack decides the item number; the rack brand decides the gear.

Whole-plate SBS cryotube Channel configuration Item No.
0.5 ml / 0.75 ml / 1.0 ml 8 channels 695008
2.0 ml 6 channels 695006

One unit, several brands. The cap opener gear can be customized to fit multiple brands of SBS cryovials, so a rack from a different supplier does not automatically mean a second instrument. State the brand, cap style and tube volume when you request pricing, and the gear configuration is confirmed against your racks.

Not sure which item number fits your rack? Send a photo of the vial next to a photo of the rack with your quote request — channel count and gear are then matched to what you actually run. Contact the team with your plate details.

Semi-Automated Screw Cap Decapper/Recapper, Multichannel

Performance and specification snapshot

What the Published Specification Covers

These are the parameters that carry the purchase decision. Use them against your plate count, your bench environment and your documentation requirements.

Channel options 6 or 8 channels
Cap operation time 3 seconds
Standby time ≥30 days
Noise during cap operations ≤5 dB
Display LED digital display screen on the second-generation lid opener
Rotation speed Optional
Vial compatibility SBS cryovials in whole-plate format
Gear head Customizable for multiple brands of SBS cryovials
Item numbers 695006 (6-channel, 2.0 ml) · 695008 (8-channel, 0.5 / 0.75 / 1.0 ml)
Packaging specification pcs/carton

Reading the numbers at the bench. A 3-second cycle is the figure to use when estimating how long a full plate occupies the unit, and ≤5 dB is the figure to quote to anyone sharing the room. The ≥30-day standby rating matters for labs that run plates in irregular batches rather than every day: the unit is specified to remain ready between sessions, and rotation speed is a separate option rather than a standard inclusion.

Semi-Automated Screw Cap Decapper/Recapper, Multichannel

Scenario to configuration

Four Common Starting Points and the Configuration Each Points To

Match the description closest to your lab, then confirm the single variable that decides the order: the tube volume inside the rack.

01

A 2.0 ml archive

Points toItem 695006, 6-channel, specified for 2.0 ml whole-plate SBS cryotubes.

Confirm before quotingThat the archive racks are whole-plate SBS format and not loose-tube trays.

02

Small-volume plates

Points toItem 695008, 8-channel, specified for 0.5 ml, 0.75 ml and 1.0 ml whole-plate SBS cryotubes.

Confirm before quotingWhich of the three volumes is dominant, so the gear is set for the plate you run most.

03

Racks from more than one brand

Points toA standard channel count with a customized cap opener gear, since the gear can be customized to fit multiple brands of SBS cryovials.

Confirm before quotingThe brand and cap style of every rack type in circulation, not just the newest one.

04

Stepping up from manual capping

Points toThe semi-automated multichannel unit: the operator keeps loading and unloading racks, while 6 or 8 channels handle the caps in a 3-second cycle.

Confirm before quotingBench footprint, the position of the LED digital display for the operator, and whether rotation speed should be included.

Fit check

SBS Cap and Rack Fit Check Before You Request a Quote

Compatibility is decided by four details. Collecting them first shortens the quote from a back-and-forth exchange to a single confirmed configuration.

  1. 1

    State the tube volume

    2.0 ml whole-plate SBS cryotubes point to the 6-channel item 695006. 0.5 ml, 0.75 ml and 1.0 ml whole-plate SBS cryotubes point to the 8-channel item 695008.

  2. 2

    Confirm the rack is whole-plate SBS format

    The unit is specified for SBS cryovials handled as a whole plate. Loose tubes or partial trays need to be discussed before the configuration is fixed.

  3. 3

    Name the rack brand and cap style

    The cap opener gear can be customized to fit multiple brands of SBS cryovials. List every rack brand in use so one gear specification covers them.

  4. 4

    Send the photo and get the gear confirmed

    Email a photo of the vial and the loaded rack to rongdaplastic@rongdaindustry.com or submit it with the quote request. The channel count and gear are then confirmed before pricing is issued.

Buyer evaluation checklist

Seven Questions to Ask Any Decapper Supplier

These questions work on any multichannel decapper quote, not just this one. Use them in an internal review to compare offers on the same footing.

  • Can the gear head be customized for our SBS cryovial brand, and who confirms the fit — the supplier or us?
  • Which item number matches our tube volume: 6-channel for 2.0 ml, or 8-channel for 0.5 to 1.0 ml?
  • Is the cap operation speed quoted per cycle, and was the 3-second figure measured on a full plate?
  • What documentation pack ships with the unit — ISO9001, ISO13485, CE Report, DNase and RNase Test Report, endotoxin and irradiation certificates?
  • Are spare gear heads available, and what is the lead time on a replacement gear?
  • Is rotation speed included in the quoted configuration or priced as an option?
  • What inputs does the supplier need to quote accurately: tube volume, rack brand, plate format and annual plate count?

Request a Configuration Quote

Three inputs decide the configuration: the tube volume in the rack, the rack brand, and how many plates you expect to run. Send them together and the channel count, gear specification and optional rotation speed are quoted in one pass. Custom gear heads for additional SBS cryovial brands are quoted per project.

  • Tube volume — 2.0 ml points to 695006, while 0.5 / 0.75 / 1.0 ml points to 695008
  • Rack brand and format — confirm whole-plate SBS and name every brand in use
  • Expected plate volume and bench environment — for the 3-second cycle and ≤5 dB figures to be assessed against your lab

Email rongdaplastic@rongdaindustry.com · Phone +86 136 1676 7326

Related Reading

Three notes to help clarify product requirements before contacting the supplier.

How Should Distributors Evaluate a Cryovial Decapper Manufacturer?

A distributor’s first shortlist for a cryovial decapper depends on verified product identity, tube-volume fit, and the quality of technical answers.

Read article

SBS Cryovial Cap and Rack Fit for Multichannel Decapping Equipment

A matching volume label and an SBS name describe what a tube is meant to be, while cap geometry and rack spacing decide whether a decapper can actually grip it.

Read article

Multichannel Cryovial Decapping in Biobank Sample Workflows

Multichannel cryovial decapping belongs to the narrow part of biobank work where caps are opened and closed repeatedly, and the useful question is workflow fit rather than a headline speed number.

Read article

Frequently Asked Questions

which item number fits 2.0 ml whole-plate sbs cryotubes?

item 695006 is the 6-channel configuration specified for 2.0 ml whole-plate sbs cryotubes.

which item number fits 0.5 ml, 0.75 ml and 1.0 ml whole-plate sbs cryotubes?

item 695008 is the 8-channel configuration specified for 0.5 ml, 0.75 ml and 1.0 ml whole-plate sbs cryotubes.

what cap operation time and noise level are listed?

the cap operation time is listed as 3 seconds, and noise during cap operations is listed as ≤5 db.

can the cap opener gear be customized for different sbs cryovial brands?

yes. the cap opener gear can be customized to fit multiple brands of sbs cryovials; provide the rack brand and cap style so the gear specification can be confirmed.

what standby time, display, and rotation-speed options are available?

standby time is ≥30 days. the second-generation lid opener has an led digital display screen, and rotation speed is optional.

which certificates and test reports are listed?

the page lists iso9001, iso13485, ce report, dnase and rnase test report, migration of specific elements and phthalates test report, bacterial endotoxin test report, and certificate of irradiation.

Leave a message
Name *
Email *
Phone
Message *
We use Cookie to improve your online experience. By continuing browsing this website, we assume you agree our use of Cookie.